Before you can use this script, you need to create several folders to include the parts you need to do the update:
- /v6: includes the 6.5.15 firmware which is needed to update to v7 (snom3X0-6.5.15-SIP-j.bin)
- /v6ux: includes the 3.38 Linux system also needed for v7 but can only be installed once the firmware is 6.5.15 (snom3X0-3.38-l.bin)
- v6to7: this folder includes the special firmware that will update v6 to v7 while keeping all settings (snom3X0-update6to7-7.1.30-bf.bin)
- v7: the normal firmware files for phones that already have v7 installed
To test it, you can simply use an URL like .../snom-firmware.asp?UA=Mozilla/4.0+(compatible;+snom320-SIP+6.5.15;+snom320+jffs2+v3.36;+snom320+linux+3.38) which will tell the script you would like to use the User agent of a Snom 320.
Once all these files are in place, you might use the following ASP script:
# Auto Update Skript
# Coypright (C) 2007-2008 TeX HeX
# http://texhex.blogspot.com
# All Rights Reserved
<%
'Example URLs (for testing):
'.../snom-firmware.asp?UA=Mozilla/4.0+(compatible;+snom320-SIP+6.5.10;+snom320+jffs2+v3.36;+snom320+linux+3.25)
'.../snom-firmware.asp?UA=Mozilla/4.0+(compatible;+snom320-SIP+6.5.15;+snom320+jffs2+v3.36;+snom320+linux+3.38)
'../snom-firmware.asp?UA=Mozilla/4.0+(compatible;+snom320-SIP+7.1.30)
'Definition of download URLs
URL_BASE="http://my-server.internal.company.com/snom"
URL_BASE_V6=URL_BASE & "/v6"
URL_BASE_V6_UX=URL_BASE & "/v6ux"
URL_BASE_V6TO7=URL_BASE & "/v6to7"
URL_BASE_V7=URL_BASE & "/v7"
URL_V6_FW_300=URL_BASE_V6 & "/snom300-6.5.15-SIP-j.bin"
URL_V6_FW_320=URL_BASE_V6 & "/snom320-6.5.15-SIP-j.bin"
URL_V6_FW_360=URL_BASE_V6 & "/snom360-6.5.15-SIP-j.bin"
URL_V6_UX_300=URL_BASE_V6_UX & "/snom300-3.38-l.bin"
URL_V6_UX_320=URL_BASE_V6_UX & "/snom320-3.38-l.bin"
URL_V6_UX_360=URL_BASE_V6_UX & "/snom360-3.38-l.bin"
URL_V6TO7_FW_300=URL_BASE_V6TO7 & "/snom300-from6to7-7.1.30-bf.bin"
URL_V6TO7_FW_320=URL_BASE_V6TO7 & "/snom320-from6to7-7.1.30-bf.bin"
URL_V6TO7_FW_360=URL_BASE_V6TO7 & "/snom360-from6to7-7.1.30-bf.bin"
URL_V7_FW_300=URL_BASE_V7 & "/snom300-7.1.30-SIP-f.bin"
URL_V7_FW_320=URL_BASE_V7 & "/snom320-7.1.30-SIP-f.bin"
URL_V7_FW_360=URL_BASE_V7 & "/snom360-7.1.30-SIP-f.bin"
'''URL_V7_FW_370=URL_BASE_V7 & "/snom370-7.1.30-SIP-f.bin"
'----------STOP EDITING-------------------
Dim CRLF
CRLF=chr(13) + chr(10)
Function Log(Text)
Response.Write("# " & Text)
Response.Write(CRLF)
End function
Function SendOutFirmware_V6
Log("Sending v6 Firmware")
Call SendOutFirmware(URL_V6_FW_300,URL_V6_FW_320,URL_V6_FW_360)
End Function
Function SendOutLinux_V6
Log("Sending v6 Linux")
Call SendOutFirmware(URL_V6_UX_300,URL_V6_UX_320,URL_V6_UX_360)
End Function
Function SendOutFirmware_V6to7
Log("Sending v6 to v7 Firmware")
Call SendOutFirmware(URL_V6TO7_FW_300,URL_V6TO7_FW_320,URL_V6TO7_FW_360)
End Function
Function SendOutFirmware_V7
Log("Sending v7 Firmware")
Call SendOutFirmware(URL_V7_FW_300,URL_V7_FW_320,URL_V7_FW_360)
End Function
Function SendOutFirmware(url300, url320, url360)
'Only write out "firmware:"" tag if it's in the night (21:00 = 9 PM, 05:00 = 5 AM)
if ( (hour(now())>=21 or hour(now())<=5) or sNow="1" ) then
'if true then
Dim sURL
pos=InStr(sUA,"snom300")
if pos>0 then
sURL=url300
end if
pos=InStr(sUA,"snom320")
if pos>0 then
sURL=url320
end if
pos=InStr(sUA,"snom360")
if pos>0 then
sURL=url360
end if
if len(sURL)>0 then
Response.Write("firmware: " + sURL)
Response.Write(CRLF)
else
Log("Unable to get download URL!")
end if
else
'Debug output, I don't think Snoms can actually undestand this :)
Log("Firmware download disabled: It's not in the night! We have now: " + cstr(now()) )
end if
End Function
Dim sUA
sUA=Request.QueryString("UA")
if len(sUA)=0 then
Log("Parameter UA is empty, defaulting to HTTP_USER_AGENT")
sUA=Request.ServerVariables("HTTP_USER_AGENT")
Response.Write(CRLF)
end if
Dim sNow
sNow=Request.QueryString("Now")
'Debug output, just for reference
Log("Parameter [USER AGENT] is --> " + sUA)
Log("Parameter [Now] (direct update) is --> " + sNow)
'Try to find out the current firmware version
Dim iPosStart,iPosEnd,sTmp
iPosStart=0
iPosEnd=0
sTmp=""
'Start searching
Log("Searching firmware version")
iPosStart=InStr(sUA,"-SIP")
if iPosStart>0 then
sTmp=Right(sUA,len(sUA)- (iPosStart+4)) '+4 to cut the "SIP " part
Call Log("Version sniffing - part 1: " + sTmp)
'now search for next ;
iPosEnd=InStr(sTmp,";")
if iPosEnd>0 then
sTmp=left(sTmp,iPosEnd-1)
Call Log("Version: " + sTmp)
else
'maybe a new 7.x phone - search for ")"
iPosEnd=InStr(sTmp,")")
if iPosEnd>0 then
sTmp=left(sTmp,iPosEnd-1)
Call Log("Version: " + sTmp)
end if
end if
end if
'Log sTmp
Dim sCurVersion
sCurVersion=""
'Now check if the version can be found!
if iPosStart<=0 or iPosEnd<=0 then
'No version info found, send to last v6 release!
Call Log("No version info found!")
Call SendOutFirmware_V6()
else
'Okay, we have a version! If this is 6.5.15 we need to send out the newest linux!
sCurVersion=sTmp
Call Log("Found version: " & sCurVersion)
if CInt(left(sCurVersion,1))<=6 and sCurVersion<>"6.5.15" then
Call Log("Version is 6 or below but not 6.5.15!")
Call SendOutFirmware_V6()
else
'Is this 6.5.15?
If sCurVersion="6.5.15" then
'Do we need to do a linux update?
iPosStart=0
iPosEnd=0
sTmp=""
Log("Searching linux version")
iPosStart=InStr(sUA," linux")
if iPosStart>0 then
sTmp=Right(sUA,len(sUA)- (iPosStart+6)) '+4 to cut the " linux" part
Call Log("Version sniffing - part 1: " + sTmp)
'now search for )
iPosEnd=InStr(sTmp,")")
if iPosEnd>0 then
sTmp=left(sTmp,iPosEnd-1)
Call Log("Version: " + sTmp)
end if
end if
if iPosStart<=0 or iPosEnd<=0 then
Log("Unable to find linux version!")
else
if sTmp<>"3.38" then
Log("Version to old, sending new linux!")
Call SendOutLinux_V6()
else
'Firmware is 6.5.15 and linux version okay!
'-> Update to 7.1.30!
Call SendOutFirmware_V6to7()
end if
end if
else
'Firmware is not 6.5.15/UX 3.38, more like 7+
Call SendOutFirmware_V7()
end if
end if
end if
Log("Done!")
%>

0 comments: